Lantronix XPress-DR - Industrial Ethernet Device Server - XSDRIN-02


Connect enterprise (ERP,MES) systems to factory floor devices without disturbing existing control networks, Configurable serial interface supports RS-232, RS-422, or RS-485, RoHS Compliant.   Learn more about the product
Price:$295.40
Quantity:
Service Plan:
Add Item
eCOST Part#: 7130031
Mfr Part#: XSDRIN-02
Usually Ships:
Availability:
Platform: Universal
Manufacturer:
UPC:0754889161306
Customer Rating:
(0)
No Reviews

 

"List price" is the suggested retail price provided to us by our vendors. We make no representation that a substantial number of these products have been sold or offered for sale at the list price. Actual retail prices in your area may be substantially different. Since we sell products on a national basis, it is not possible to know if our merchandise is sold at list price in any particular location or at any particular time. "You Save" reflects the difference between our price and the vendor provided list price shown on our sites. Since the list price may be different than the actual retail prices in your area, you may not actually realize a savings of this amount.

Manufacturers sometimes ask that retailers not display a price if it drops below a certain amount. The "Click here to see Lowest Price" message indicates that the price of the item is so low that the manufacturer requested that it not be advertised (that is, displayed). In a brick-and-mortar store, you would probably have to ask a salesperson what the price of the product is. At eCOST, by clicking on "Click here to see Lowest Price" you are essentially asking to see the price, at which point we show it to you.

 Free Shipping
 Free Shipping on Orders Over $50 and under 30 pounds (Orders Up to 30lbs qualify. Excludes shipments to AK & HI.)

Highlights

– Connect enterprise (ERP,MES) systems to factory floor devices without disturbing existing control networks
– Allow remote firmware upgrades, saving money and time from manual upgrades
– IAP version supplies many industrial communication protocols
– Configurable serial interface supports RS-232, RS-422, or RS-485
– 10Base-T/100Base-TX Ethernet (RJ45)
– Isolated serial and Ethernet ports
– FM-approved for hazardous locations Class I, Div. 2
– RoHS Compliant

PLCs, Drives, Process Controls, Power Monitoring Equipment, Barcode Scanners, and other factory floor serial devices

The XPress-DR and XPress-DR-IAP Device Servers allow virtually any serial device to be connected to a new or existing Ethernet network.

By encapsulating serial data and transporting it over Ethernet, the XPress-DR/DR-IAP allows virtual serial links to be established over Ethernet. By using these units, limited-distance, point-to-point, direct serial connections can now be extended within the plant, throughout the facility, or across the global enterprise.

When used in conjunction with an OPC server, most Windows based HMI, SCADA, and PC-based control applications have full access to information in the connected device. Existing COM-port based Windows applications can access network-enabled devices using our Com Port Redirector software. Redirector software allows the creation of virtual serial ports, which can be mapped to the remote device servers over Ethernet and connected to the XPress-DR and XPress-DR-IAP.

The XPress-DR-IAP installable communication drivers allow specific support for various industrial communication protocols. With native support for these protocols, devices that previously allowed only one connection can now support multiple connections simultaneously.

Flexible configuration options allow the unit to be set up locally using the serial port, or remotely over Ethernet using Telnet or a common web browser. Included Windows based configuration software simplifies the process of installing communication drivers and configuring them for use with attached devices. Flash memory provides for maintenance-free, non-volatile storage, and allows future system upgrades.

Packaged in a rugged DIN-rail mount case and featuring 2000V galvanic isolation, 1500V Ethernet isolation, a wide 0° to 60°C operating range, and a 9-30VDC/9-24VAC power input, the XPress-DR and XPress-DR-IAP are ideal for any industrial application.

Features and Specifications

Serial Interface

– Interface: RS-232, RS-422, or RS-485
– Connector: Screw terminals or RJ45
– Data Rates: 300 to 115,200 bps
– Characters: 7 or 8 data bits
– Parity: odd, even, none
– Stop Bits: 1 or 2
– Software: XON/XOFF
– Hardware: RTS/CTS

Network Interface

– Standards: ARP, UDP/IP, TCP/IP, ICMP, SNMP, BOOTP, DHCP, TFTP, Telnet, and HTTP
– Interface: 10Base-T/100Base-TX Ethernet
– Connector: RJ45

Indicators

– Ready, Fault/Configuration, Activity, Link, Serial Transmit Data, Serial Receive Data

Management

– SNMP, serial, Telnet, and HTTP (web browser)

Isolation

– Ethernet: 1500 Vrms
– Serial: 2000 Vrms

Power

– Input: 9 to 30VDC/9-24VAC, 3W maximum
– Connector: Screw terminals for power and ground

Software

– Included Windows 95/98/ME/NT/2000-based configuration software simplifies initial setup
General
Device Type Device server
Width 3.5 in
Depth 2.4 in
Height 1.4 in
Networking
Form Factor External
Connectivity Technology Wired
Data Link Protocol Ethernet, Fast Ethernet, RS-232, RS-422, RS-485
Network / Transport Protocol TCP/IP, UDP/IP, ICMP/IP
Remote Management Protocol SNMP, Telnet, HTTP
Status Indicators Link activity, transmit, receive
Features Flow control, DHCP support, BOOTP support, ARP support
Expansion / Connectivity
Interfaces 1 x 100Base-TX - RJ-45 ¦ 1 x ¦ 1 x
Miscellaneous
Compliant Standards CSA, UL, TUV, RoHS
Software / System Requirements
Software Included Drivers & Utilities
OS Required Microsoft Windows 95/98, Microsoft Windows 2000, Microsoft Windows NT, Microsoft Windows Millennium Edition
Manufacturer Warranty
Service & Support 1 year warranty
Service & Support Details Limited warranty - 1 year
Environmental Parameters
Min Operating Temperature 32 °F
Max Operating Temperature 140 °F
Humidity Range Operating 20 - 90%
close
  View/Download Coupon
Service Net
  Description Price
 Service Net 1 Year Plan 1 Year Service Net Replacement Coverage (200 - 399.99), EXT 1 Year Plan $35.00  
 Service Net 2 Years Plan 2 Year Service Net Replacement Coverage (200 - 399.99), EXT 2 Years Plan $61.88  
 Service Net 1 Year Plan 1 Year Service Net Replacement for Refurb Product (251 - 299.99) EXT 1 Year Plan $31.99  
 Service Net 2 Years Plan 2 Year Service Net Replacement for Refurb Product (451 - 500) EXT 2 Years Plan $91.99  
 Service Net 2 Years Plan 2 Year Service Net Replacement for Refurb Product (250 - 299.99) EXT 2 Years Plan $51.99  

 

Lantronix XPress-DR - Industrial Ethernet Device Server (XSDRIN-02)

Connect enterprise (ERP,MES) systems to factory floor devices without disturbing existing control networks, Configurable serial interface supports RS-232, RS-422, or RS-485, RoHS Compliant.

0 Question(s) • 0 Answer(s)

Back to top

Rules and Regulations

0 Question(s) from the Community

Most Recent Reviews

No reviews have been submitted for this product. Be the first user to  submit a review .
 
Entrust bbb Rating Tool Twist

1940 E. Mariposa Ave. El Segundo, CA 90245 - 877.888.2678
© 1999 – 2014 eCOST